Voron TempFluct

Aus Hobby Wiki
Version vom 24. Dezember 2025, 20:27 Uhr von Uwedamm (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „The thermal conductivity of aluminium is lambda=220W/m/K The max distance of the resistors is 70 mm I estimate the area A[mm^2]=70*10mm^2, through which the po…“)
(Unterschied) ← Nächstältere Version | Aktuelle Version (Unterschied) | Nächstjüngere Version → (Unterschied)
Zur Navigation springen Zur Suche springen

The thermal conductivity of aluminium is lambda=220W/m/K The max distance of the resistors is 70 mm I estimate the area A[mm^2]=70*10mm^2, through which the power of the load-resitor passes I estimate the distance from the middle of the resistor to the resistor itself l=35mm At 110° ~ 30% of the 750W Heatbed, which was installed before was sufficient. -> P~4W = 250W/30/2 (half of the power of one of the resistors flows through that area to the heat bed surface. 4*35*1000/220/700 K ~ 1K

I would assume, that my thermal cameras resolution is not sufficient to detect such small variations in the temperature over the bed. Will give it a try in the next few weeks. (Beginning of 2026)